Air compressor failure: What is the cause of the high exhaust pressure of the screw air compressor?
Reason analysis of high exhaust pressure of screw air compressor:
- The intake valve is stuck and cannot be closed, resulting in constant loading.
- Gas consumption suddenly decreases.
- The loading solenoid valve is faulty, blocked and not completely blocked.
- The unloading solenoid valve is faulty, the unloading fails, and the pressure keeps rising until the unloading is not completed.
- The pressure setting is too high.
- The pressure sensor is faulty.
Solution for high exhaust pressure of screw air compressor:
- Remove the intake valve, if the jamming is not serious, smooth the rusty place with sandpaper, and add some oil to lubricate. Seriously replace the maintenance package or assembly directly.
- Check the change of gas consumption, if the gas consumption is properly reduced, the high value of unloading pressure.
- Check and eliminate the solenoid valve failure.
- Adjust the pressure switch setting.
- Replace the pressure sensor.