Precautions for turning on and off the screw air compressor

With the continuous reform and upgrading of screw air compressor technology, various operations are also very simple and easy, such as starting and shutting down. Screw air compressor start-up process:
1. Check the cooling water system valve
2. Turn on the cooling water pump and water tower fan
3. Press the “Start” button
4. Observe whether the air compressor is abnormal
5. Press the “Load” button to make the air compressor work
6. Observe whether the system is abnormal
Screw air compressor shutdown process:
1. Confirm whether downtime is required
2. Press the “Uninstall” button
3. Long press the “Stop” button
4. Wait about 15 minutes
5. Turn off the cooling tower and cooling water pump
Precautions:
1. Check whether the power supply is normal before starting the machine;
2. The cooling pump and fan must be turned on first, and then turned on;
3. After starting up, if there is abnormal noise or large vibration of the device, shut down immediately;
2. When the air compressor is running, do not press the emergency stop button in non-emergency situations, and operate according to the shutdown steps for normal shutdown;
3. Be sure to keep the cooling water running for a period of time after stopping the machine before stopping the cooling water.
Precautions for restarting the screw air compressor after long-term shutdown!
1. Long-term shutdown, especially when the shutdown is more than 2 months, it is necessary to re-maintain the screw air compressor before starting it for use.
2. Check whether the parts of the screw air compressor are fastened. If there is any looseness, check the fastening.
3. Check the amount of oil in the oil and gas barrel. The amount of oil should not be too much, nor too little, and the oil level should be between the two lines.
4. Check the quality of lubricating oil. Open the bottom of the oil and gas barrel, let a small amount of oil flow out, observe the color of the lubricating oil, if it has turned black, you need to replace the lubricating oil, or re-maintain the screw air compressor before it can be used.
5. Drain the condensed water. When the screw air compressor is stopped and there is no pressure in the body, open the oil drain valve at the bottom of the oil and gas barrel to discharge the condensed water generated during the operation of the air compressor.
Sollant Focus on Energy Saving