Air compressor common troubleshooting
- The machine does not start: check the main switch and power cord, check the motor;
- The machine does not load after starting up: adjust the setting value of the pressure switch or replace the pressure switch, check or replace the solenoid valve;
- The compressor does not unload, and the safety valve releases: adjust the setting value of the pressure switch or replace the pressure switch, check or replace the solenoid valve;
- Excessive oil consumption: use oil according to the recommendation, lower the oil level to the normal position, remove the oil return line for cleaning, and replace the oil-gas separator filter element;
- The exhaust pressure is lower than the specified value: reduce the gas consumption or increase the compressor, check the system leakage, clean or replace the intake filter element, replace the oil-gas separator filter element, check or replace the solenoid valve, overhaul the intake control valve, replace belt, adjust the setting value of the pressure switch;
- Compressor high temperature protection shutdown: improve the environmental ventilation conditions, clean or clean the cooler, add oil to the specified position, replace the oil filter;
- The compressor runs unloaded, the exhaust pressure still rises slowly, and the safety valve releases: check or replace the solenoid valve, overhaul the intake control valve, overhaul the unloading pipeline;
- Safety valve relief: overhaul or replace the safety valve, overhaul the minimum pressure valve, replace the filter element of the oil-gas separator, overhaul or replace the pressure switch, check the intake control valve or solenoid valve.
Sollant Focus on Energy Saving